SECABO TCC Lite (EN)

secabo_TCC_Lite_EN-0.png

Congratulations on the purchase of your Secabo heat press!
To ensure that you can start production smoothly with your machine, please read these operating
instructions carefully.
Any form of reproduction of these operating instructions requires the written permission of Secabo
GmbH. Technical data and product features are subject to change and errors excepted.
Secabo GmbH accepts no liability for direct or indirect damage resulting from the use of this
product.

 

Precautions

Please read these notes and precautions carefully before operating the unit for the first time!

  • Never reach your hands into the heat press when it is connected to the power supply,
    especially when it is switched on and heated up - risk of burns!

  • Never open the housing and do not make any changes to the unit yourself.

  • Should it be necessary to open the heating plate cover after explicit request by Secabo
    customer service, it is recommended to wear respiratory protection and to handle the
    insulation wool inside with gloves. The insulation wool should only be disposed of in a
    closed bag.

  • Make sure that neither liquids nor metal objects get inside the heat press.

  • Make sure that the socket outlet used is earthed. Note that a heat press may only be
    operated from a socket outlet that is protected by a residual current circuit breaker.

  • Disconnect the heat press from the mains when not in use.

  • Always operate the heat press out of the reach of children and never leave the machine
    switched on unattended.

  • Make sure that the unit is only used in dry rooms.

If you are unable to meet one or more of the above safety requirements, or if you are
unsure whether they all apply, please contact our technical support.

Scope of delivery

 

 

Mechanical base of the
transfer press with heating
element and base element

secabo_TCC_Lite_EN-1.jpg

 

 

Controller Box
CL01

secabo_TCC_Lite_EN-2.jpg

C13 cold
appliance
connection
cable

secabo_TCC_Lite_EN-3.png

Device description

secabo_TCC_Lite_EN-4.jpg

 

a. Main switch (without illustration)

b. Display

c. Control panel with push buttons

d. IEC socket and earth connection Controller (not shown),
internal connections

e. Clamping lever for transfer objects

f. Exchangeable base element

g. Cover heating element and heating element

h. Press lever

 

 

Assembly and commissioning

Place the base frame of the TCC Lite heat press securely on a stable table.

  • Position the CL01 controller box above the rear centre of the TCC Lite transfer press
    base frame and slide the threaded bolts on the controller box into the slots on the base
    frame. Tighten the hand nuts securely.

secabo_TCC_Lite_EN-5.jpg
  • Attach the small 6-pin connector from the back of the base rack to the matching socket
    on the outside right of the controller box.

  • Attach the large 5-pin connector from the surface of the heater to the matching socket on
    the outside right of the controller box.

secabo_TCC_Lite_EN-6.jpg
  • Plug the protective earth cable from the HPC01 controller into the terminal provided at the
    rear of the base frame.

  • Plug the supplied C13 IEC power cable into the back of the controller box and connect it to
    an earthed socket, which must have an earthed connection and be protected by a fuse and
    earth leakage circuit breaker.

The TCC Lite heat press is now ready for operation.

Controller components and operation

secabo_TCC_Lite_EN-7.png

 

Digital Controller

 

 

secabo_TCC_Lite_EN-8.jpg

Operation

  • Connect the TCC Lite Transfer Press to the mains using the power cable supplied.

  • Switch on the TCC Lite heat press.

  • OFF" appears in the display.

  • After switching on, "-f-" (Fahrenheit) or "-c-" (Celsius) appears.

  • Use the arrow keys to select the desired temperature unit.

  • Press the "OK" button. Now the "Temp" LED lights up.

  • Use the arrow keys to select the desired temperature.

  • Press the "OK" button. Now the "Time" LED lights up.

  • Use the arrow keys to select the desired duration of the pressing process.

  • Press the "OK" button. The display will initially show LO, and only as soon as the
    temperature has exceeded 100°C will the current temperature of the TCC Lite heat press
    be displayed. The press will now heat up to the set temperature.

  • An acoustic signal sounds when the heat press is heated up.

  • Now the transfer press can be closed via the press lever to carry out transfers.

  • When the press is closed, the timer starts to count down, and about half a second later
    the magnet is activated, which is indicated by a flashing light at CDL in the display. Only
    then is the press locked.

  • After the timer has expired, there is also an acoustic signal, after which the press opens
    automatically.

Carry out transfers

  • Switch on the heat press via the main switch.

  • Store the desired parameters for temperature and time and confirm each of them as
    described above. For information on how to change the settings on the controller, see
    the preceding paragraphs.

  • You can regulate the contact pressure by increasing or decreasing the lever travel by
    turning the small hand screw on the underside of the press. Turning clockwise
    increases the contact pressure and turning anticlockwise decreases it.

  • Tension the transfer object with the tension lever to the left of the base element as
    tightly and flat down as possible to avoid creases in the transfer.

  • No setting can be changed during the pressing process.

 

Notes

  • Note that the heating plate and the transfer objects are hot and there is a risk
    of burns.

  • Switch off the machine when it is not needed.

  • Please note that it takes a certain amount of time for the press to cool down
    again after it has been switched off. There is a risk of burns until it has cooled
    down completely!

Maintenance and cleaning

All maintenance work must be carried out when the press is switched off and has cooled down. The
plug must be removed from the socket beforehand. Only carry out maintenance work after
consulting our technical support.
The press should be cleaned regularly with a soft cloth and a mild household cleaner to remove
adhesive residues, dust, etc. Do not use scouring pads, solvents or petrol!

Recommended times and temperatures

These values are only approximate, may vary from material to material and must be checked
before pressing.

Material

Temperature

Pressure

Pressing Time

Material

Temperature

Pressure

Pressing Time

Flockfoil

170°C - 185°C
338°F - 365°

light-medium

25s

 

Flexfoil

160°C - 185°C
320°F - 365°F

medium-high

25s

Flex for sublimation

180°C - 195°C
356°F - 383°F

medium-high

10s - 35s

Sublimation on
mugs

200°C
392°F

medium-high

150s - 180s

Sublimation on tiles

200°C
392°F

high

120s - 480s
(depending on the thickness of the material)

Sublimation on
puzzles

200°C
392°F

light-medium

50s

Sublimation on
mousepads

200°C
392°F

medium

20s - 40s

Sublimation on
textiles

200°C
392°F

medium-high

30s - 50s

Sublimation on
metal plates

200°C
392°F

high

10s - 50s
(depending on the thickness of the material)

Important note: Before each production, own tests should be made with the respective
transfer materials and carrier media. The above values and the manufacturer's specifications
are only indicative. Washing resistance and behaviour during transfer must be determined in
separate tests.

No guarantee can be derived from the recommended values. It is always up to the user todetermine and apply the settings applicable under his or her specific conditions.

Note for textile finishes: After the pressing process, the textiles must cool down before any
backing media can be removed from the transfer material. The hotmelt adhesive in the
transfer material has only developed its adhesive strength when cold. If the adhesive does
not adhere when cold, the pressing process may have been too cold or too short.

Technical data

Transfer Press

Secabo TCC Lite

Transfer Press

Secabo TCC Lite

Type

automatic opening cap press

Working area size

15cm x 8cm

Swing angle

35°

Max. temperature

225 °C

Max. preset time

999s

Max. working pressure

250g/cm2 / 3.56 psi

Pressure setting

Height-adjustment of the heat plate via hand wheel

 

Power Supply

230V / 50Hz - 60Hz, 1.0kW

Environment

+5°C - +35°C / 30% - 70% humidity 41°F -
95°F - 70% humidity

Weight

15kg

Weight with packaging

22kg

Closed dimensions (W x H x D)

24 cm x 59 cm x 53 cm

Opene dimensions (W x H x D)

24 cm x 71 cm x 53 cm

 

 